Type of covering of compensating lead wire
PVC coating | Vinyl is used for insulation of standard type general compensating lead wires. Operating temperature range:-20~90℃ |
---|---|
Fiberglass coating | Excellent properties such as non-flammability, heat resistance, electrical insulation, mechanical strength and chemical stability. Operating temperature range:0~150℃ |
Silicone rubber coating | It is an insulating material that has little change in physical characteristics and is resistant to chemical, oil, weather, and ozone. Operating temperature range:-25~180℃ |
Fluoropolymer coated(FEP,PFA) | Fluoropolymer is an insulating material with excellent heat resistance, chemical resistance, electrical insulation, high frequency characteristics, weather resistance, mechanical strength, and pressure resistance. Operating temperature range:-250~200℃(FEP), -200~260℃(PFA) |