Products

Radiation thermometer IS50-LO+ IGA50-LO+

Product name

Fiber optic radiation thermometer

 

Model number

IS50-LO+ IGA50-LO+

 

IS50-LO+・IGA50-LO + is a fast-responding (fastest 1msec) fiber-optic radiation thermometer.
Temperatures of various metal surfaces, processing and processing processes can be measured with high accuracy by detection at short wavelengths.

Usage

    • IS50-LO+・IGA50-LO + can be used for thermometry in general metallurgical heat treatment.
      Ideal for metal molds, preheating, annealing, tempering, welding, forging, hardening, sintering, melting, soldering, rolling, brazing, and laser application measurements.

Features

    • Suitable for measuring the temperature of samples with severe temperature changes or moving at high speed because of fast response (fastest 1msec)
      (However, since the L type is wide range, the response time is automatically extended around the lower temperature limit to reduce noise.)
    • Compatible with small spot measurement. Small samples can also be measured. 0.45 From φ /88mm.
    • A laser pilot button and temperature indicator are built into the main unit, and parameters can be set.
      Adjustment on the site has become easier.
    • Eight lenses are available in two types. The measuring area covers 88mm~4500mm.
    • A movable focusing lens (TypeII) is used to optimize the spot diameter at any position.
    • It has a built-in maximum value holding circuit, so it is also suitable for measuring moving objects.
    • The laser pilot light makes it easy to check the measurement position.
    • • Data-recording and parameter setting can be performed using the dedicated measurement software (for Windows) provided as a standard-attached product.

Specifications

Temperature range IS50-LO+ 550 to 1400°C, 600 to 1600°C, 650 to 1800°C, 750 to 2500°C, 900 to 3300°C
(L type) 550 to 1800°C
IGA50-LO+ 300 to 1300°C ,350 to 1800°C, 450 to 2500°C
(L type) 250 to 1350°C, 300 to 2000°C, 350 to 2500°C
Detection wavelength IS50-LO+ 0.7 ~ 1.1μm
IGA50-LO+ 1.45 ~ 1.8μm

・DC current 0 to 20mA/4~20mA can be selected for analogue output.
・The scaling function of the minimum 50°C width enables replacement with the conventional model.
・The interface can also be switched to a RS485 with RS232 and bus-connectivity.

Basic system configuration diagram

Accessories

3834-370 Type I Mounting bracket 1

3834-380 Type I Mounting bracket 2

3834-230 Type II Mounting bracket

3834-390 Type I II dual-purpose ball-and-socket mounting bracket

3835-170 Type I Air purging pipe

3835-180 Type II Air purging pipe

   

List of Radiation thermometer and thermal image

【英語版】山里産業コーポレートサイト
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.